Home | Rules & Guidelines | Register | Member Rides | FAQ | Members List | Social Groups | Calendar | Mark Forums Read |
Tech Talk Technical Discussion About The Nissan 240SX and Nissan Z Cars |
|
Thread Tools | Display Modes |
09-02-2014, 12:16 PM | #1 |
Sr20det EGI relay buzzing won't start
Before I start, I've researched this topic for awhile an have tried several things so far, seems to be a common problem. But I've tried everything on all of the threads I've seen. Just would like some extra input. Thanks in advance.
So I have a 93 s13 with a red top sr20det swap. Has jim wolf ecu, stock internals, stock t-25, nismo 555 injectors, z32 maf, blah blah blah. Went on vacation in June for a week or so an when i came back the egi relay was buzzing an car would not start. I have charged battery, replaced terminals, replaced the connector to my fuel pump which was corroded, walboro 255 pump, I've replaced both relays that we're buzzing. The egi relay an the one right next to it. Put a new fuel filter in, new spark plugs, tested spark. Just will not start up. I got it to run once a little bit when I sprayed starter fluid in. But ran bad an shutoff. Any help or advice I'd appreciate it! Thanks guys! |
|
Sponsored Links |
04-10-2019, 09:09 PM | #2 |
Join Date: Feb 2011
Location: Ottumwa, Iowa
Age: 30
Posts: 22
Trader Rating: (0)
Feedback Score: 0 reviews
|
Bringing back an old thread.
Need help Fuel pump only primes when jumping the relay. IT WILL NOT DO ANYTHING UNLESS JUMPED Wtf do I do now? Drive it? Lol I don’t think the ecu pin is burnt And I think my grounds are good. Dunno lol |
04-11-2019, 08:30 AM | #3 |
Premium Member
Join Date: Jun 2003
Location: torrance, ca
Age: 39
Posts: 12,407
Trader Rating: (129)
Feedback Score: 129 reviews
|
ive seen a number of #62 and #63 ecu that burn the pin that triggers the EGI relay. The best solution I've found is to manually command the relay. The ecu sends a ground signal to that relay, commanding it to change state. So, wire as follows;
relay ------- switch ------- ground to chassis. This makes a good kill switch too, so hide it somewhere. |
04-11-2019, 11:37 AM | #4 |
Join Date: Feb 2011
Location: Ottumwa, Iowa
Age: 30
Posts: 22
Trader Rating: (0)
Feedback Score: 0 reviews
|
Ok cool man, so your saying, essentially run a toggle switch with a relay, so I don’t mess things up.?
Because yes Ik it’s dangerous if I’m in a wreck, the way I have it, the pump runs full speed until the key is turned off. It’s very tempting to just drive it the way it is Is my only options to do it like you said. 1. Relay, switch, ground to chassis? Or 2 run it with the wire jump? Lol Does it hurt to run it this way? |
04-11-2019, 11:47 AM | #5 |
Premium Member
Join Date: Jun 2003
Location: torrance, ca
Age: 39
Posts: 12,407
Trader Rating: (129)
Feedback Score: 129 reviews
|
1: verify that the problem is ACTUALLY what you think it is (determine if the ecu IS or IS NOT grounding the relay, which clicks it on/off
2: its up to YOU if you decide to replace the ecu with one that is not burnt, or if you just want it to operate the egi relay off a switch. 3: yes, instead of the egi relay getting its ground from the ecu, you run it to a switch, and then ground to the chassis. |