Hey guys. I have a baby on the way and the car is here to stay so now I have to go through the pain of installing AC as I live in NC where its easily 100 OUTSIDE of the car. I am have searched and came up with a list of what I need to make ac work in my car (s14 with s13 sr20).

1. I have an sr AC compressor (hooks up to block and belt operated)
2. I have the s14 AC condenser (the radiator looking thing)
3. I know I'll need the lines. the guy I got the car from removed ALL of them....

What else do I need?
Danger_Dorn is offline   Reply With Quote
Sponsored Links
Old 07-17-2013, 03:21 PM   #2
jr_ss
Post Whore!
 
Join Date: Dec 2005
Location: Pa
Posts: 6,052
Trader Rating: (34)
jr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nice
Feedback Score: 34 reviews
Send a message via AIM to jr_ss
Receiver drier, new O-rings for your lines and a charge. The AC lines can be made with the factory lines and having the SR comp fittings welded on.
__________________
My SR20VET
jr_ss is offline   Reply With Quote
Old 07-17-2013, 04:01 PM   #3
Danger_Dorn
Zilvia Member
 
Danger_Dorn's Avatar
 
Join Date: Oct 2012
Location: Jacksonville NC
Age: 30
Posts: 265
Trader Rating: (0)
Danger_Dorn is an unknown quantity at this point
Feedback Score: 0 reviews
I don't have any of the lines though. Where could I get them? NAPA? I'm at like ground zero here minus the compressor and condensor
Danger_Dorn is offline   Reply With Quote
Old 07-17-2013, 04:47 PM   #4
jr_ss
Post Whore!
 
Join Date: Dec 2005
Location: Pa
Posts: 6,052
Trader Rating: (34)
jr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nice
Feedback Score: 34 reviews
Send a message via AIM to jr_ss
WTB thread is your friend. There are multiple part out threads going on. Ask around, someone has to have them.
__________________
My SR20VET
jr_ss is offline   Reply With Quote
Old 07-17-2013, 07:37 PM   #5
Danger_Dorn
Zilvia Member
 
Danger_Dorn's Avatar
 
Join Date: Oct 2012
Location: Jacksonville NC
Age: 30
Posts: 265
Trader Rating: (0)
Danger_Dorn is an unknown quantity at this point
Feedback Score: 0 reviews
So I know what parts I need. My question is now, I have an SR20 compressor and a us s14 condenser...will the lines and stuff all bolt up ok or do I need to convert threads and such?
Danger_Dorn is offline   Reply With Quote
Old 07-18-2013, 06:35 AM   #6
Mikester
Nissanaholic!
 
Mikester's Avatar
 
Join Date: Jun 2007
Location: Kathleen, GA
Age: 50
Posts: 1,938
Trader Rating: (0)
Mikester is a well-known jackass
Feedback Score: 0 reviews
My advice:

You have an S13 SR in an S14. JDM lines, fittings etc may be a PITA to source out. I recommend you get an S14 KA24DE compressor & PM Codyace. He makes the adapters for USDM compressors to SR's. This way, you can source out the USDM S14 lines and they will plug & play.

I run an S13 SR w/KA24DE(S13) compressor in my S13... Codyace's adapter kit works perfectly and all of my USDM lines etc connect flawlessly.

There, now you have two choices
__________________
Mikester is offline   Reply With Quote
Old 07-18-2013, 02:19 PM   #7
Danger_Dorn
Zilvia Member
 
Danger_Dorn's Avatar
 
Join Date: Oct 2012
Location: Jacksonville NC
Age: 30
Posts: 265
Trader Rating: (0)
Danger_Dorn is an unknown quantity at this point
Feedback Score: 0 reviews
Thanks Mikester. I might make a how to thread when I get going on it. My baby isn't due until Dec so I have some time lol
Danger_Dorn is offline   Reply With Quote
Old 07-18-2013, 04:09 PM   #8
Danger_Dorn
Zilvia Member
 
Danger_Dorn's Avatar
 
Join Date: Oct 2012
Location: Jacksonville NC
Age: 30
Posts: 265
Trader Rating: (0)
Danger_Dorn is an unknown quantity at this point
Feedback Score: 0 reviews
Another question. So with my heater core lines...I don't have the valve/cable system thing anymore so do I need to incorporate a valve from say...home depot in there? If I leave it open it will just blow hot right? Also I will need to plug up parts of the AC right? Any special wiring to get it back in there? I have a WS harness btw.

EDIT: Just checked...it does have the plugs sorry for asking stupid questions
Danger_Dorn is offline   Reply With Quote
Old 07-18-2013, 04:16 PM   #9
Danger_Dorn
Zilvia Member
 
Danger_Dorn's Avatar
 
Join Date: Oct 2012
Location: Jacksonville NC
Age: 30
Posts: 265
Trader Rating: (0)
Danger_Dorn is an unknown quantity at this point
Feedback Score: 0 reviews
So I have both a s14 ka compressor and an s13 redtop sr compressor. Correct me if Im wrong. The redtop comp. will bolt up to my redtop motor just fine but the lines will not work with s14 ones? and the KA needs and adapter but will bolt up just fine to my s14 lines?
Danger_Dorn is offline   Reply With Quote
Old 07-18-2013, 06:35 PM   #10
Kingtal0n
Post Whore!
 
Kingtal0n's Avatar
 
Join Date: Jul 2005
Location: South Florida
Age: 38
Posts: 4,646
Trader Rating: (17)
Kingtal0n has a reputation beyond reputeKingtal0n has a reputation beyond reputeKingtal0n has a reputation beyond reputeKingtal0n has a reputation beyond reputeKingtal0n has a reputation beyond reputeKingtal0n has a reputation beyond reputeKingtal0n has a reputation beyond reputeKingtal0n has a reputation beyond reputeKingtal0n has a reputation beyond reputeKingtal0n has a reputation beyond reputeKingtal0n has a reputation beyond repute
Feedback Score: 17 reviews
Send a message via AIM to Kingtal0n
Quote:
Originally Posted by Danger_Dorn View Post
So I have both a s14 ka compressor and an s13 redtop sr compressor. Correct me if Im wrong. The redtop comp. will bolt up to my redtop motor just fine but the lines will not work with s14 ones? and the KA needs and adapter but will bolt up just fine to my s14 lines?
Heres how I do it everytime i want A/C on an Sr20det.

Find A/C compressor lines that plug into the compressor. Make sure the O-ring matches up right, and they do not interfere with each other.

Now, use your chassis A/C lines and cut them such that they mate up straight to the compressor and do not interfere with anything. then tig weld them together. Make sure you remove all the burrs , debris, and clean with acetone before welding... because once its welded up you cannot clean the insides free of metal shavings. make sure you remove the oring and schrader valves before welding.

Only way to get around welding the lines is to find a compressor/bracket for sr20det that uses the same a/c lines as your chassis does.
or find a way / make a bracket that will allow your KA compressor to bolt to the redtop. And figure out how to make the belt work.
__________________
5.3/4l80e/turbo 240sx playthrough:
https://tinyurl.com/turbo240
Kingtal0n is offline   Reply With Quote
Old 07-19-2013, 06:23 AM   #11
Mikester
Nissanaholic!
 
Mikester's Avatar
 
Join Date: Jun 2007
Location: Kathleen, GA
Age: 50
Posts: 1,938
Trader Rating: (0)
Mikester is a well-known jackass
Feedback Score: 0 reviews
Danger Dorn- PM Codyace.
__________________
Mikester is offline   Reply With Quote
Old 07-20-2013, 07:43 PM   #12
Danger_Dorn
Zilvia Member
 
Danger_Dorn's Avatar
 
Join Date: Oct 2012
Location: Jacksonville NC
Age: 30
Posts: 265
Trader Rating: (0)
Danger_Dorn is an unknown quantity at this point
Feedback Score: 0 reviews
Ok so I have managed to find a redtop compressor with the lines, and all of the s14 hoses. The only problem I have encountered is the lines off the compressor don't match up to the larger s14 one so I think I am either going to get them welded or maybe make an adaptor from brass fittings from home depot. Suggestions?
Danger_Dorn is offline   Reply With Quote
Old 07-20-2013, 07:51 PM   #13
jr_ss
Post Whore!
 
Join Date: Dec 2005
Location: Pa
Posts: 6,052
Trader Rating: (34)
jr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nicejr_ss is just really nice
Feedback Score: 34 reviews
Send a message via AIM to jr_ss
Have them welded...
__________________
My SR20VET
jr_ss is offline   Reply With Quote
Reply

Bookmarks


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -6. The time now is 12:45 AM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2021, vBulletin Solutions Inc.
vB.Sponsors
Copyright © 1998 - 2019, Zilvia.net™